Description
Compatible Models
D3K/D4C/D4D/D4G/D4K/D5K/D5H/D5M/D5N/D5H/D6D/D6M/D6N/D6H/D6M/D6N/D6K/D6R//D7G/D7F/D7H/D7R/D8R/D8K/D8N/D9N/D9G/D9R/304E/305/306E2/307D/308D/312D2/313D/314D/315D/318D2/320B/320C/320D/320D2/320NGH/322BL/323D/325C/325D/326D2/329D/330B/330C/330D/336D/336D2/345D/349D/365C/374FL/390DL/390FL/416B/416D/416E/ 416F/428C/428E/428F/CS533E/CS533D/CS563C/CS533D/CB14B/CW34/CB7/AP655F/AP355F/AP655D/120H/120G/140H/ 140K/140G/14M3/16G/16M3/740B/773E/777D/773D/772G/740B/773B/935/938F/966C/966H/950F/950GC/980C/990H/992G
Characteristics | HYDO Advanced 10 | Typical Diesel Engine Oil API CF SAE 10W | Typical Premium Industrial Hydraulic Oil, HVLP or HV | HYDO Advanced 10 Advantages |
SAE Viscosity Grade | 10W | 10W | Varies | |
Viscosity | Better wear protection, wider operating temperature range | |||
cSt @ 40?C (ASTM D445) | 42 | 40 | 46 | |
cSt @ 100?C (ASTM D445) | 6.7 | 6.3 | 8 | |
Viscosity Index (ASTM D2270) | 114 | 105 | 146 | |
Viscosity after Shear 2?????? (cSt, during use) | 6.7 | 6.3 | 6.6 | |
FZG Gear Test DIN 51534, Fail Stage?? 3 | 12 | 12 | 11 | |
35VQ25 Vickers Total Wear Test | 33 mg | 40-90 mg | <90 mg | |
4 Ball (40kg/30min/600rpm/93?C ASTM D4172) | 0.37?? mm | Varies | Varies | |
Pour Point, ?C (ASTM D97) | -39 | -30 | -36 | |
Pumping @ -30?C mPaS (ASTM D4684) | 15,000 | Varies | Varies | |
Zinc, % wt. (ASTM D4951) typical | 0.09 | Varies | <0.040 | |
Copper Strip Corrosion? 4? (3 hr, ASTM D130) | 1A @ 150?C | 1 @ 100?C | 1 @ 100?C | Corrosion protection |
Rust Protection 5?? (ASTM D665B) | Pass | Varies | Varies | |
Oxidation stability, hours (ASTM D943) | >5,000 | 2,000 hours | 2,000 hours | Longer drain interval; lower owning and operating costs |
Long Drain Interval, confirmed by field testing | Yes | No | No | |
Filterability, Wet, E DIN ISO 13357-1 | Pass | Fail | Pass | Filter bypass, filter plugging,? contamination control |
Air Release @ 50?C (ASTM D3427) | 4 minutes | 7-10 minutes | 7-13 minutes | Better air release reduces cavitation damage |
Foam Test 6 | Varies | Varies | ||
Seq. 1 ml. (ASTM D892) | 0/0 | |||
Seq. 2 ml. (ASTM D892) | 5/0 | |||
Seq. 3 ml. (ASTM D892) | 0/0 | |||
Cleanliness | No interference with optical particle counters | Interferes with optical particle counters | Varies | Accurate contamination Control |
Ability to keep water in emulsion | Yes | Yes | No | Sludge control and water damage prevention |