HYDO ADVANCED10/20LT

$91.25

Above price will be slightly different based on location because of transportation charges.

Part Number : 3096942

Part Name : HYDO ADVANCED10/20LT

Please click below link to download the flyer:

https://www.parts-mspcat.com/wp-content/uploads/2021/06/PEHJ0182-02-HYDO-Advance-10.pdf

11 in stock

SKU: 3096942 Category:

Description

Compatible Models

D3K/D4C/D4D/D4G/D4K/D5K/D5H/D5M/D5N/D5H/D6D/D6M/D6N/D6H/D6M/D6N/D6K/D6R//D7G/D7F/D7H/D7R/D8R/D8K/D8N/D9N/D9G/D9R/304E/305/306E2/307D/308D/312D2/313D/314D/315D/318D2/320B/320C/320D/320D2/320NGH/322BL/323D/325C/325D/326D2/329D/330B/330C/330D/336D/336D2/345D/349D/365C/374FL/390DL/390FL/416B/416D/416E/ 416F/428C/428E/428F/CS533E/CS533D/CS563C/CS533D/CB14B/CW34/CB7/AP655F/AP355F/AP655D/120H/120G/140H/ 140K/140G/14M3/16G/16M3/740B/773E/777D/773D/772G/740B/773B/935/938F/966C/966H/950F/950GC/980C/990H/992G

Characteristics HYDO Advanced 10 Typical Diesel Engine Oil API CF SAE 10W Typical Premium Industrial Hydraulic Oil, HVLP or HV HYDO Advanced 10 Advantages
SAE Viscosity Grade 10W 10W Varies
Viscosity Better wear protection, wider operating temperature range
cSt @ 40?C (ASTM D445) 42 40 46
cSt @ 100?C (ASTM D445) 6.7 6.3 8
Viscosity Index (ASTM D2270) 114 105 146
Viscosity after Shear 2?????? (cSt, during use) 6.7 6.3 6.6
FZG Gear Test DIN 51534, Fail Stage?? 3 12 12 11
35VQ25 Vickers Total Wear Test 33 mg 40-90 mg <90 mg
4 Ball (40kg/30min/600rpm/93?C ASTM D4172) 0.37?? mm Varies Varies
Pour Point, ?C (ASTM D97) -39 -30 -36
Pumping @ -30?C mPaS (ASTM D4684) 15,000 Varies Varies
Zinc, % wt. (ASTM D4951) typical 0.09 Varies <0.040
Copper Strip Corrosion? 4? (3 hr, ASTM D130) 1A @ 150?C 1 @ 100?C 1 @ 100?C Corrosion protection
Rust Protection 5?? (ASTM D665B) Pass Varies Varies
Oxidation stability, hours (ASTM D943) >5,000 2,000 hours 2,000 hours Longer drain interval; lower owning and operating costs
Long Drain Interval, confirmed by field testing Yes No No
Filterability, Wet, E DIN ISO 13357-1 Pass Fail Pass Filter bypass, filter plugging,? contamination control
Air Release @ 50?C (ASTM D3427) 4 minutes 7-10 minutes 7-13 minutes Better air release reduces cavitation damage
Foam Test 6 Varies Varies
Seq. 1 ml. (ASTM D892) 0/0
Seq. 2 ml. (ASTM D892) 5/0
Seq. 3 ml. (ASTM D892) 0/0
Cleanliness No interference with optical particle counters Interferes with optical particle counters Varies Accurate contamination Control
Ability to keep water in emulsion Yes Yes No Sludge control and water damage prevention